§ 6707.1. Test A.  


Latest version.
  • With the sliding sash in the normal position, a concentrated load of 150 pounds (667.2 N) shall be applied separately to each sash member incorporating a locking device, at a point on the sash member within 6 inches (152.4 mm) of the locking device, in the direction parallel to the plane of glass that would tend to open the window.

(Ord. 99-0040 § 69 (part), 1999.)