CHAPTER 7A [SFM] - MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE  


§ 701A.1. Scope.
§ 701A.3. Application.
§ 701A.3.1. Application date and where required.
§ 702A. DEFINITIONS
§ 703A.2. Qualification by testing.
§ 703A.3. Approved agency.
§ 703A.5.2. Weathering.
§ 703A.6. Alternates for materials, design, tests, and methods of construction.
§ 705A.2. Roof coverings.
Appendix 710. A.3.2
§ 710A.4. Requirements.
§ 1507.3.1. Deck requirements.
§ 1613.7. Modifications to ASCE 7.
§ 1613.7.1. ASCE 7, 12.12.3.
§ 1613.7.2. ASCE 7, 12.2.3.1, Exception 3.
§ 1613.7.3. ASCE 7, Section 12.11.2.2.3.
§ 1613.7.4. ASCE 7, Section 12.8.1.3.
§ 1613.8.1. Purpose.
§ 1613.8.2. Scope.
§ 1613.8.3. Definitions.
§ 1613.8.4.1. General.
§ 1613.8.4.2. Base level diaphragm-downhill direction.
§ 1613.8.4.2.1. Base for lateral force design defined.
§ 1613.8.4.2.2. Base shear.
§ 1613.8.5.1. General.
§ 1613.8.5.2. Location of primary anchors.
§ 1613.8.5.3. Design of primary anchors and diaphragm struts.
§ 1613.8.5.4. Limitations.
§ 1613.8.6.1. General.
§ 1613.8.6.2. Secondary anchor capacity and spacing.
§ 1613.8.6.3. Design.
§ 1613.8.7. Diaphragms below the base level-downhill direction.
§ 1613.8.7.1. Diaphragm defined.
§ 1613.8.7.2. Design force.
§ 1613.8.7.3. Design force-resistance-primary anchors.
§ 1613.8.7.4.1. General.
§ 1613.8.7.4.2. Secondary anchor capacity.
§ 1613.8.7.4.3. Design.
§ 1613.8.8. Primary and secondary anchorage and diaphragm strut design.
§ 1613.8.9.1. General.
§ 1613.8.9.2. Base shear.
§ 1613.8.9.3. Vertical distribution of seismic forces.
§ 1613.8.9.4. Drift limitations.
§ 1613.8.9.5.1. General.
§ 1613.8.9.5.2. Wood structural panel sheathed walls.
§ 1613.8.9.5.3. Reinforced concrete or masonry shear walls.
§ 1613.8.9.6. Limitations.
§ 1613.8.10.1. Footings and grade beams.
§ 1613.8.10.2. Protection against decay and termites.
§ 1613.8.10.3. Sill plates.
§ 1613.8.10.4. Column base plate anchorage.
§ 1613.8.10.5. Steel beam to column supports.
§ 1704.2.3. Statement of special inspections.
§ 1704.6. Structural observations.
§ 1705.3. Concrete Construction.
§ 1807.1.4. Permanent wood foundations systems.
§ 1807.1.6. Prescriptive design of concrete and masonry foundation walls.
§ 1809.7. Prescriptive footings for light-frame construction.
§ 1809.12. Timber footings.
§ 1810.3.2.4. Timber.
§ 1905.1. General.
§ 1905.1.7. ACI 318, Section 14.1.4.
§ 1905.1.8. ACI 318, Section 17.2.3.
§ 1905.1.9. ACI 318, Section 18.7.5.
§ 1905.1.10. ACI 318, Section 18.10.4.
§ 1905.1.11. ACI 318, Section 18.12.6.
§ 2304.10.1. Fastener requirements.
§ 2305.4. Quality of nails.
§ 2305.5. Hold-down connectors.
§ 2306.2. Wood-frame diaphragms.
§ 2306.3. Wood-frame shear walls.
§ 2307.2. Wood-frame panel shear walls.
§ 2308.6.5.1. Alternate braced wall (ABW).
§ 2308.6.5.2. Portal frame with hold-downs (PFH).
§ 2308.6.9. Attachment of sheathing.

Note: This Chapter has been amended by Los Angeles County and is applicable to all occupancy groups.


(Ord. 2016-0053 § 3, 2016.)